Installations | 28 September 2026

Joints for seismic-insulated buildings: the LSP system

Joints for seismic-insulated buildings: the LSP system

In buildings with seismic isolation at the base, the structure must be able to accommodate the movements predicted by the system.

However, this has an important design consequence: spaces and connection systems must be provided along the perimeter of the building to accommodate the planned movements without hindering them.

It is in this context that it fits LSP of the MIGUMAX series, large joint system distributed in Italy by CPR GIUNTI Edilizia Servizi srl and developed for applications characterized by particularly high movements. The CPR documentation indicates the MIGUMAX series as a solution also intended for seismic-isolated structures and, more generally, for buildings characterized by high movements.

Why seismic-isolated buildings require specific joints

In a traditional structure, a joint must absorb the movements and deformations foreseen by the design.

In the case of a construction with seismic isolation, the problem takes on a different scale, since the isolated structure generally moves rigidly to an extent comparable to the travel of the isolators foreseen in the structural design.

The joint must therefore satisfy two needs simultaneously: leave the structure the degrees of freedom provided by the insulation system and make the crossings usable in relation to the intended use envisaged in the project.

Therefore, in addition to the amount of movement, the intended use of the area, the type of transit, the finishes and the geometry that the joint must follow become preponderant in order to take into account the vector combination of movements in the 3 directions.

LSP MIGUMAX: a system for large seismic movements

Il LSP system It is designed for large joints and allows for absorption movements in three directions.

Its operation is based on a telescopic articulation system (cylindrical hinge) on one side and on a inclined support and sliding surface inside the profile on the other (skate). The CPR technical data sheet defines this element as a “ramp-shaped support”. The central element consists of a 15mm thick aluminum plate, which slides on this inclined plane and is hinged on the opposite side. The LSP system can be customized to suit the structural gap and the expected movement by modifying the dimensions of the central plate (LSP SPECIAL).

The standard version has an installation height of 45 mm.

How the LSP system is built

The behavior of the joint does not depend on a single element, but on the interaction of the different components that make up the system.

  • 3D Telescopic Hinge: constitutes one of the articulation elements of the system.
  • Sliding plane: accompanies the movement of the moving part of the joint.
  • Steel aligners (pins): contribute to the alignment of the system elements.
  • Sealing and sound-absorbing rubbers: are integrated into the profile configuration.
  • Surface prepared for R12 or R13 treatment: allows for a non-slip finish on the central plate.

These are elements that help to understand why LSP is not simply a plate designed to cover a large gap, but a real articulated system designed to accompany the movement of the structure.

LSP MIGUMAX joint for seismic-insulated buildings – system components | CPR GIUNTI

LSP SPECIAL: when the joint is adapted to the project

Not all buildings have joints that can be traced back to standard configurations.

For this reason, in addition to the standard range, the system can be sized according to the required movements, giving rise to the configurations LSP SPECIAL.

The particular articulation system also allows for the creation in the factory special pieces, including transitions between different configurations and 90° intersections, allowing the joint to follow more complex paths, while respecting the elastic congruence of the expected seismic displacements.

As an example, the configurations are shown below: Lsp  Special specially designed for three construction sites, with different intended uses, built in Sulmona (L'Aquila)At the 'Cotugno Hospital in Naples and for Clinic Humanitas (Catania).

Sulmona: the joint follows the ramp, changes in height and 90° angles

In the draft seismic adaptation of a building for residential use Sulmona (L'Aquila), the insulation of the building at the base made it necessary to create a joint along the perimeter of the construction.

One of the most interesting parts of the project concerns the access ramp to the basement.

At this point, the joint does not follow a simple linear path: it must accompany the changes in height of the ramp and continue through changes in direction.

They were then made 90° angle special pieces with vertical corners (ramps) equipped with special retaining systems, continuously using the same LSP system, sized for a joint with a width equal to 420 mm.

The Sulmona case highlights a particularly important aspect in the design of joints for seismic-isolated buildings: it is not only how much the joint has to move that matters, but it takes on particular relevance how to ensure continuity of any planimetric-altimetric trend of the structural joint.

Cotugno Hospital in Naples: a 680 mm joint

A different need arose in the project to connect two buildings forming part of theCotugno Hospital in Naples.

In this case it was necessary to cover a joint of width equal to 680 mm, with a movement required by the project of ± 300 mm., with the particularity of ensuring the continuity of the LSP system in correspondence with a pillar flush with the joint, a condition resolved with a special solution that includes a translation plate and a corner version.

This intervention highlights how the solution cannot be identified exclusively through a standard profile and the use of special solutions becomes necessary.

The Cotugno construction site therefore represents another example in which the the joint design takes into account the current state in full compliance with the specific conditions of the work.

Humanitas Istituto Clinico Catanese: joints up to 800 mm and movements up to ±640 mm

The third intervention concerns a new construction Humanitas with seismic isolation.

In this project, in addition to the usual problems of seismically isolated structures, i.e. dealing with the displacements between a structure isolated on the boundary, it was necessary to deal with the displacements between two facing structures, both seismically isolated, therefore the LSP system was sized for two different configurations:

  • 400-450 mm joint with required movement of ±320 mm;
  • 800mm joint with required movement of ±640mm.

The second case reaches particularly significant dimensions and movement capacity, highlighting how the use of special solutions very often becomes the norm.

Three construction sites, three different needs technically resolved with the LSP system

Sulmona (L'Aquila)The difficulty is primarily geometric; the joint must follow a ramp, changes in height, and 90° changes in direction, while preserving the functional continuity and aesthetic appeal of the joint system.

Cotugno Hospital in Naples: the main issue, besides the size of the opening, equal to 680 mm, is the need to use corner versions due to the presence of pillars along the structural joint.

Humanitas Clinical Institute of Catania (Misterbianco, Catania): dimensions and movements reach even higher values, up to an 800 mm joint with a required movement of ±640 mm.

Three different conditions that show how, in the design of buildings in seismic zones with or without seismic isolation at the base, the joint must be evaluated as a integral part of the project and not as a simple finishing element.

The choice of the joint starts from the characteristics of the work

The width of the passage, expected movements, geometry, intended use and type of transit can substantially change the required configuration.

The standard LSP range, as per the technical data sheet reported in the documentation MIGUA/CPRGIUNTI It is intended for use on driveway joints for cars between 100 and 500 mm of width with 'standard' movements, while for more complex needs, customized configurations can be developed for widths and movements assigned using solutions LSP SPECIAL.

For this reason, in projects characterized by seismic isolation and large movements, identifying the joint requires an evaluation of the actual conditions of the work.

CPR GIUNTI Edilizia Servizi srl supports designers and companies in identifying the solutions for structural joints, integrating the solutions into its range MIGUA also dedicated to applications with large widths and high seismic movements.

 

Technical documentation:

Download the LSP System CPR flyer (PDF)

FAQ on joints for seismic-insulated buildings

What is the purpose of the joint in a seismic-insulated building?

It must allow for the expected movements between the isolated structure and the surrounding parts, while maintaining the functional continuity of the affected surfaces.

What is the LSP system?

LSP is a large-area joint system from the MIGUMAX series. Its design includes a telescopic joint and a sliding system that accommodates movement in three directions.

How much movement can an LSP joint absorb?

There is no single value. The examples shown illustrate the ability to easily cover the allowable displacements of the insulation systems currently in use.

Is it possible to make special corners and pieces?

Yes. The examples illustrated demonstrate the possibility of manufacturing special pieces for horizontal corners and/or inclined ramps in the factory.

Are you a designer, do you represent a construction company?

The expertise and experience of our technical staff is at your disposal free of charge. Request information now, you will be contacted by one of our experts who will guide you in identifying the most suitable structural joint and in drafting the tender specifications.
Contact Us